18 — The doctor's report in the app: time in ranges, average, GMI, variability

2026-10-17 · investigation report · JVM renders of the real code (Robolectric native graphics), Sukrara for Mac renders, unit tests

LibreView’s report for the doctor (the AGP page) sums up a period in a few numbers with goals next to them. The user wants the same numbers in Sukrara, in the app and in the widgets: for example GMI in the third slot of a widget, where a 30-day time-in-range ring would otherwise go, faded or at full strength.

LibreView’s page has two panels: Time in Ranges (a stacked bar from very low to very high with the share and goal of each range, very high + high and low + very low summed against their goals) and Glucose Metrics (average glucose, GMI in % and mmol/mol, glucose variability as % CV, each with its goal). The user’s own page isn’t reproduced here (it’s their health data).

report report dark

The Glucose report card on the home screen (wearer and follower), 14 days by default (1, 7, 14, 30). Synthetic data.

slots

The slots beside the number: a time-in-range ring or a report number (GMI, average glucose, CV) over its own window, faded by position or at full strength. Last row: GMI, average and CV for 14 days.

widget

A 4×2 widget with GMI for 30 days in the third slot, at full strength.

What How it was checked Result
GMI and its units GlucoseStatsTest.gmi: a steady 141 mg/dL (the report’s average) GMI 6.68 % → 6.7 %, 49.5 → 49 mmol/mol, as on the report
Mean, SD, CV are time-weighted GlucoseStatsTest.cvTimeWeighted: one hour at 100 in 1-minute readings, one at 200 in 5-minute history mean 150, SD 50, CV 33 % (counting readings would give mean 117)
Goals the consensus targets (below) applied to each number met = green with ✓, not met = orange
Mac see Mac
Number How Goal (type 1 and type 2 diabetes)
Time in ranges the six bands of 16, every reading weighted by the time it stands for very high < 5 %, above range (high + very high) < 25 %, target > 70 %, below range < 4 %, very low < 1 %
Average glucose time-weighted mean < 154 mg/dL
GMI 3.31 + 0.02392 × average (Bergenstal et al. 2018); in mmol/mol: (GMI − 2.152) × 10.929 < 7 % / < 53 mmol/mol
Glucose variability coefficient of variation: SD / average, time-weighted ≤ 36 %

The goals are the international consensus (Battelino et al., Diabetes Care 2019) that LibreView prints as “Goals for type 1 and type 2 diabetes”. The consensus asks for 14 days with the sensor active ≥ 70 % of the time; the card says so when a window has less.

Time-weighting matters here as in 16: the wearer’s history mixes 1-minute live readings and 5/15-minute backfill, and counting readings would let the live minutes outweigh the backfilled hours.

The rings of 16 become slots. Each of the three has:

  • a kind: time-in-range ring, GMI, average glucose or CV;
  • a window: 12 h, 1, 3, 7, 14 or 30 days (new);
  • fainter than the main one: on by default for the second and third; off draws it at full strength.

A report number is drawn as a gauge in the same circle: the value in the middle (“6.6 %”, “136”, “27 %”), the kind and window under it, and an arc on the number’s scale (GMI 5–10 %, average 70–250 mg/dL, CV 0–60 %) with a tick at the goal, green when it’s met. Defaults: 1-day ring, 7-day ring, 14-day GMI as the third (shown when the slot count is 3). Settings → Graph & time in range → Beside the number. The wearer now keeps 31 days of readings (was 15).

The same numbers through the shared Swift renderer (SukraraGraph.swift): metrics, goals, slot kinds and the gauge.

menubar report widget gmi
The menubar dropdown: the card, then Glucose report (14d) in the LibreView layout (window in the Graph submenu, reportDays) A medium widget with GMI 14 d in the third slot at full strength
  • Slots are UserDefaults slots ("TIR:86400:1,TIR:604800:1,GMI:1209600:1"), editable per slot (kind, window, fainter) in the Graph submenu. The widget file carries each slot’s numbers precomputed from the Mac’s reading store, which now keeps 31 days.
File What
graph/GlucoseMetrics.kt mean, SD, CV, GMI, the goals
graph/GlucoseCard.kt SlotKind, RingSpec.kind/faded, MetricGauge
graph/GraphSettings.kt, graph/GraphData.kt slots setting, cached metrics per window from the role’s store
ui/ReportCard.kt the report card (GlucoseReportContent is pure, so the gallery renders it)
app/src/test/…/graph/ReportGallery.kt, GraphGallery.slots the pictures above
Added Discarded (why)
Glucose report card on both home screens (time in ranges with goals, average, GMI % and mmol/mol, CV, coverage note) the report’s AGP percentile curve and daily profiles (the chart and the time-at-level distribution already show the shape)
Slots: ring, GMI, average or CV, each with its window and fade —
30-day windows; 31 days kept on the wearer —